Heat shrink Bus bar tubing ,Thin wall

2024/7/25 viewers
  • BrandDEEM
  • TypeDB-BL
  • order
Introduction
Applications
Suitable for insulation and protection of bus bar against accidental flashover up to 1
KV. Ideal for using in switchgears cabinets where space is limited and air spacing
between bus bars need to be minimized.
Features
Flame retardant thin wall cross-linked polyolefin
Bus bar insulation and protection
Reduces bus bar clearance requirement
Halogen free, RoHS compliant
Protects against short circuit and electrical leakage caused by small animals.
Various
Operating temperature: -40 to +105 °C. Minimum shrink temperature: 125 °C. Voltage
class: 1KV
Standard color: Black

Technical Data
Property Test Method Values
Physical Tensile strength ASTM D2671 214 MPa
Elongation at break ASTM D2671 N400%
Tensile strength at aging(136°C/168hrs) ASTM D2671 212 MPa
Elongation at break at aging(136°C/168hrs) ASTM D2671 ≥300%
Tensile strength resistance to selected fluids
             (23℃/168hrs)
IEC60684-2 ≥8MPa
Elongation at break resistance to selected fluids
                (23℃/168hrs)
IEC60684-2 ≥250%
Density ASTM D2671 1.15-1.25
Thermal endurance IEC216 125℃
Water absorption (23°C/336hrs) ASTM D570 S0.5%
Low Temperature flexibility (-40°C/4hrs) ASTM D2671 No cracking
Heat shock(225°C/4hrs) ASTM D2671 No drop, no flow
Cutting test(130°C/168hrs) Raychem method
5mm Length cutting

along longitudinal, no
cracking
Electrical Volume resistivity ASTM D2671 ≥1014Ω.cm
Dielectric strength ASTM D2671 218/KV/mm
Chemical Flammability ASTM D2671 Self-extinguish in 30s
Smoke  index
Copper corrosion(158C/168hrs)
Dimensions
As Supplied  (mm) After Recovery (mm)
Standard Length
m/roll
Inside Diameter
Min. (D)
Inside Diameter
Min.(D)
Wall Thickness
Min. (WT)
25 12 0.8 50
30 15 0.8 50
40 20 0.9 50
50 25 0.9 25
60 30 1.0 25
70 35 1.1 25
80 40 1.2 25
90 45 1.3 25
100 50 1.3 25
120 60 1.3 25
150 75 1.5 25
180 90 1.5 25
•Length as standards. 1 m. or 1,22 m. sticks, special Lengths or cut pieces available on request.